INNER FAN BELT REMOVAL
DANGER!
Be sure to unplug the power cord from the outlet before assembling or disassembling the
tool. Accidental starting of the motor may cause bodily injury.
1. Removethegrindingwheelandangeassembly(Seesectionforgrindingwheeland
angeinstallationandremoval)
2. Remove the Phillips screw used to secure the inner fan belt cover. Remove the inner
fan belt cover to expose the inner fan belts and pulleys.
3. Removetheinnerfanbeltbygrabbingitwithyourthumbandindexngerandpulling
it up while rotating. It could take two or three turns to remove the fan belt.
Figure-35
Figure-36
Inner Belt
Cover
Phillips
Screw
Inner Fan Belt Cover
Fan Belt Removal